DC voltage (DCV)
| Range |
Accuracy |
Resolution |
| 6V |
± (0.5%+3) |
0.001V |
| 60V |
0.01V |
| 600V |
0.1V |
| 1000V |
± (0.8%+10) |
1V |
AC voltage(DCV)
| Range |
Accuracy |
Resolution |
| 6V |
± (0.8%+3) |
0.001V |
| 60V |
0.01V |
| 600V |
0.1V |
| 750V |
± (1.2%+10) |
1V |
DC Current (DC mA)
| Range |
Accuracy |
Resolution |
| 60mA |
± (1.2%+10) |
10uA |
| 600mA |
100uA |
DC Current (DC uA)
| Range |
Accuracy |
Resolution |
| 600uA |
± (1.2%+10) |
0.1uA |
| 6000uA |
1uA |
AC Current (AC mA)
| Range |
Accuracy |
Resolution |
| 60mA |
± (1.2%+10) |
10uA |
| 600mA |
100uA |
AC Current (AC uA)
| Range |
Accuracy |
Resolution |
| 600uA |
± (1.2%+10) |
0.1uA |
| 6000uA |
1uA |
DC/AC 10A Current (DC/ACA)
| Range |
Accuracy |
Resolution |
| 6A |
± (2.0%+30) |
0.01A |
| 10A |
0.01A |
Resistance (Ω)
| Range |
Accuracy |
Resolution |
| 600Ω |
± (0.8%+5) |
0.1Ω |
| 6kΩ |
± (0.8%+3) |
1Ω |
| 60kΩ |
10Ω |
| 600kΩ |
100Ω |
| 6MΩ |
1kΩ |
| 40MΩ |
± (2.5%+3) |
10kΩ |
Capacitance(C)
| Range |
Accuracy |
Resolution |
| 60nF |
± (3.5%+20) |
10pF |
| 600nF |
100pF |
| 6uF |
1nF |
| 60uF |
10nF |
| 600uF |
100nF |
| 6mF |
± (5%+3) |
11uF |
| 30mF |
10uF |
Frequency measurement:
| Range |
Accuracy |
Resolution |
| 10Hz |
± (0.1%+3) |
0.01Hz |
| 100Hz |
0.1Hz |
| 1kHz |
1Hz |
| 10kHZ |
10Hz |
| 100kHz |
100Hz |
| 1MHz |
1kHz |
| 20MHz |
10kHz |
Temperature measurement (°C/°F)
| Range |
Accuracy |
Resolution |
| (-20-1000 )℃ |
± (1.0%+5) <400℃ ± (1.5%+15)≥400℃ |
1℃ |
| (0-1832 )℉ |
± (0.75%+5) <750℉ ± (1.5%+15)≥750℉ |
1℉ |
Square Wave Output: 50Hz/100Hz/200Hz/300Hz/400Hz/500Hz/600Hz/700Hz/800Hz/ 900Hz/1000Hz/2000HZ/4000HZ/5000HZ
Duty Cycle: range: 1%~99%;resolution: 0.1%; accuracy: ±(0.1%+2)
Diode: √(DC forward current is 5mA, voltage is 3V)
Continuity: √(no more than 50Ω)
Maximum display: 6000 (3 5/6) bits automatic polarity display
Measurement: double integral A / D conversion
Sampling rate: about 3 times per second
Overrange display: the most significant bit was "0L"
Low voltage display: symbol appears
Working environment: (0 to 40)℃, relative humidity <80%
Power supply: AAA 1.5V battery (Not included)
Volume (size): 142×70×32mm(L×W×H)
Weight: about 200g
Good News!
The Newest Oscilloscope Multimeter Of MUSTOOL MT8027 will be preorder at the end of June!
A Fully Oscilloscope witth 200MHz Sampling Rate 40MHz Bandwidth + True RMS 6000 counts dispaly digital Multimeter !!!
>>More Details Please Click Here<<<